Proposal to strengthen educational building ancient II-MOP. Venezuela

This article presents the study of structural reinforcement for a building of educational use, known as "Old Type II". The school was built before the creation of the Venezuelan Seismoresistant Covenin 1756. The results of the structural analysis showed insufficient responsiveness to servi...

पूर्ण विवरण

में बचाया:
ग्रंथसूची विवरण
मुख्य लेखकों: Yépez, José, Dikdan Jaua, María Ysabel, Andrade, Luis, Rojas de Yepez, Rosangel
स्वरूप: Online
भाषा:spa
प्रकाशित: Universidad Centroccidental Lisandro Alvarado - Decanato de Ingeniería Civil 2017
ऑनलाइन पहुंच:https://revistas.uclave.org/index.php/gt/article/view/769
टैग : टैग जोड़ें
कोई टैग नहीं, इस रिकॉर्ड को टैग करने वाले पहले व्यक्ति बनें!
विवरण
सारांश:This article presents the study of structural reinforcement for a building of educational use, known as "Old Type II". The school was built before the creation of the Venezuelan Seismoresistant Covenin 1756. The results of the structural analysis showed insufficient responsiveness to service requests, high vulnerability to seismic action and deficiencies in the quantity and distribution of reinforcing steel. For this reason, the reinforcement of the superstructure was proposed by the construction of panel walls, verifying their action on the existing piloting system. For the modeling, the values of resistance of the concrete obtained in the destructive tests made by the materials laboratory of the School of Civil Engineering of the Universidad Centroccidental Lisandro Alvarado and the soil parameters from the geotechnical study were used.