Water closets and water wastes in apartment buildin Water closets and water wastes in apartment buildings gs

This paper presents water wastes indexes obtained from an investigation in outlets and water storage tanks of five apartment buildings in Goiânia. These indexes were gathered from theoretical studies and from a water consumption audit in buildings. The stages of the water audits and the methods used...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Autor principal: Oliveira, Lúcia Helena de
Formato: Online
Idioma:por
Publicado em: ANTAC - Associação Nacional de Tecnologia do Ambiente Construído 2008
Acesso em linha:https://seer.ufrgs.br/ambienteconstruido/article/view/3433
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
id ojs-article-3433
record_format ojs
spelling ojs-article-34332008-11-22T00:18:00Z Water closets and water wastes in apartment buildin Water closets and water wastes in apartment buildings gs As bacias sanitárias e as perdas de água nos edifícios Oliveira, Lúcia Helena de Perda de água; Desperdício de água; vazamento; bacia sanitária This paper presents water wastes indexes obtained from an investigation in outlets and water storage tanks of five apartment buildings in Goiânia. These indexes were gathered from theoretical studies and from a water consumption audit in buildings. The stages of the water audits and the methods used for leakage detection are also presented. The results indicate that high indexes of water leakage and loss were detected in water closet cisterns. It is highlighted that leaks in water closet cisterns can be the cause of approximately 30% of water waste in buildings. Este artigo apresenta índices de perda de água por vazamentos provenientes de componentes de utilização e de sistemas de reservação de água de cinco edifícios residenciais multifamiliares de Goiânia. Para a obtenção desses índices foram utilizados dados de trabalhos teóricos e realizadas auditorias do consumo de água nos edifícios. São apresentadas as etapas das auditorias e os métodos utilizadas na detecção dos vazamentos. Os resultados obtidos apresentam elevados índices de vazamento e de perda de água detectados em bacias sanitárias com caixa de descarga. Ressaltam que os vazamentos em bacias sanitárias com caixa de descarga podem ser responsáveis por cerca de 30 % do desperdício de água em edifícios. ANTAC - Associação Nacional de Tecnologia do Ambiente Construído 2008-04-14 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion application/pdf https://seer.ufrgs.br/ambienteconstruido/article/view/3433 Ambiente Construído; v. 2, n. 4 (2002): Edição Especial Sistemas Prediais; 39-45 Ambiente Construído; v. 2, n. 4 (2002): Edição Especial Sistemas Prediais; 39-45 Ambiente Construído; v. 2, n. 4 (2002): Edição Especial Sistemas Prediais; 39-45 1678-8621 1415-8876 por https://seer.ufrgs.br/ambienteconstruido/article/view/3433/1850 Direitos autorais 2016 Ambiente Construído https://creativecommons.org/licenses/by/4.0
institution Universidade Federal do Rio Grande do Sul
collection OJS
language por
format Online
author Oliveira, Lúcia Helena de
spellingShingle Oliveira, Lúcia Helena de
Water closets and water wastes in apartment buildin Water closets and water wastes in apartment buildings gs
author_facet Oliveira, Lúcia Helena de
author_sort Oliveira, Lúcia Helena de
title Water closets and water wastes in apartment buildin Water closets and water wastes in apartment buildings gs
title_short Water closets and water wastes in apartment buildin Water closets and water wastes in apartment buildings gs
title_full Water closets and water wastes in apartment buildin Water closets and water wastes in apartment buildings gs
title_fullStr Water closets and water wastes in apartment buildin Water closets and water wastes in apartment buildings gs
title_full_unstemmed Water closets and water wastes in apartment buildin Water closets and water wastes in apartment buildings gs
title_sort water closets and water wastes in apartment buildin water closets and water wastes in apartment buildings gs
description This paper presents water wastes indexes obtained from an investigation in outlets and water storage tanks of five apartment buildings in Goiânia. These indexes were gathered from theoretical studies and from a water consumption audit in buildings. The stages of the water audits and the methods used for leakage detection are also presented. The results indicate that high indexes of water leakage and loss were detected in water closet cisterns. It is highlighted that leaks in water closet cisterns can be the cause of approximately 30% of water waste in buildings.
publisher ANTAC - Associação Nacional de Tecnologia do Ambiente Construído
publishDate 2008
url https://seer.ufrgs.br/ambienteconstruido/article/view/3433
work_keys_str_mv AT oliveiraluciahelenade waterclosetsandwaterwastesinapartmentbuildinwaterclosetsandwaterwastesinapartmentbuildingsgs
AT oliveiraluciahelenade asbaciassanitariaseasperdasdeaguanosedificios
_version_ 1709370536924020736