The calculus of the thermal equivalent conductivity of the ecological roof

Through the monitoring of an ecological roof located on the building of the Escuela Técnica Superior de Ingenieros Agrónomos (ETSIA) of the Universidad Politécnica de Madrid (UPM), the thermal equivalent conductivity has been determined. An equation that establishes a relationship among the energeti...

全面介紹

Saved in:
書目詳細資料
Main Authors: Machado, María V., Britto, Celina, Neila, Javier
格式: Online
語言:por
出版: ANTAC - Associação Nacional de Tecnologia do Ambiente Construído 2008
在線閱讀:https://seer.ufrgs.br/ambienteconstruido/article/view/3495
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
實物特徵
總結:Through the monitoring of an ecological roof located on the building of the Escuela Técnica Superior de Ingenieros Agrónomos (ETSIA) of the Universidad Politécnica de Madrid (UPM), the thermal equivalent conductivity has been determined. An equation that establishes a relationship among the energetic balance of a vegetable coverage in a natural environment, and the energetic balance of an ecological cover on a roof has been formulated. Three important factors have been taken into account: the quantities of absorbed, reflected, transmitted, evapotranpirated and used in the photosynthesis process solar radiation; the convective heat flow within the vegetable layer; and the conductivity heat flow. Through this process, an equation for the calculus of the thermal equivalent conductivity of the ecological roof was obtained. The result (0,12 W/m ºC) was evaluated and compared with those obtained through the essay of a sample of the same parcel carried out in the materials laboratory of the Ministerio de Fomento de España.