Efficiency evaluation of grease traps prescribed by the Brazilian standard NBR 8160:1999 as natural flotation basins
This paper evaluates Brazilian standard NBR 8160:1999 sized grease traps efficiency under natural flotation principles. Some characteristics of sanitary drainage systems effluent containing grease are presented, followed by ideal natural flotation horizontal basins sizing principles. Then, the appl...
Guardado en:
| Autor principal: | Gnipper, Sérgio Frederico |
|---|---|
| Formato: | Online |
| Lenguaje: | por |
| Publicado: |
ANTAC - Associação Nacional de Tecnologia do Ambiente Construído
2008
|
| Acceso en línea: | https://seer.ufrgs.br/ambienteconstruido/article/view/5362 |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Ejemplares similares
-
Climate parameters for thermal performance simulation according to the Brazilian standard NBR 15.575
por: Guarda, Emeli Lalesca Aparecida da, et al.
Publicado: (2020) -
QUALI-QUANTITATIVE ANALYSIS OF THE BRAZILIAN PERFORMANCE STANDARD (NBR no. 15,575/2013) AND MAIN CHALLENGES FOR UPPER LEVEL IMPLEMENTATION ON RESIDENTIAL MULTIFLOOR BUILDINGS
por: Souza, Jonas Leonardo Pessanha de, et al.
Publicado: (2018) -
Backwardness, forestry sector and territorial traps. The Province of Arauco
por: Grosser Villar, Günter Thomas, et al.
Publicado: (2019) -
Development of plug-ins focused on analyzing requirements of the Brazilian Performance Standard
por: Silva, Juliano Lima da, et al.
Publicado: (2019) -
RESIDENTIAL BUILDING DESIGN CONSIDERING THE BRAZILIAN PERFORMANCE STANDARD: ANALYSES TO WALL PARTITION
por: Oliveira, Luciana Alves, et al.
Publicado: (2012)