Thermal comfort and performance in the buildings of the new research centre of Petrobras in Rio de Janeiro
This paper presents the a study of the thermal performance of the new Petrobras research centre, CENPES II, in Rio Janeiro, including free running and air-conditioned buildings. The architectural design was the subject of a national competition in 2004, encompassing over 100.000m2 and ten buildings....
Na minha lista:
| Principais autores: | , , , , , , , , |
|---|---|
| Formato: | Online |
| Idioma: | por |
| Publicado em: |
ANTAC - Associação Nacional de Tecnologia do Ambiente Construído
2010
|
| Acesso em linha: | https://seer.ufrgs.br/ambienteconstruido/article/view/7794 |
| Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
| id |
ojs-article-7794 |
|---|---|
| record_format |
ojs |
| spelling |
ojs-article-77942010-06-09T11:56:11Z Thermal comfort and performance in the buildings of the new research centre of Petrobras in Rio de Janeiro Conforto e desempenho térmico nas edificações do novo centro de pesquisas da Petrobras no Rio de Janeiro Marcondes, Mônica Pereira Mueller, Cecília Mattos Brandão, Rafael Silva Prata, Alessandra Rodrigues Brunelli, Gustavo De Benedetto, Gisele Goncalves, Joana Soares Duarte, Denise Helena Silva Frota, Anésia Barros Thermal comfort; Natural ventilation; Energy efficiency; Tropical climate; Simulation Conforto térmico. Ventilação natural. Eficiência energética. Clima tropical. Simulação computacional. This paper presents the a study of the thermal performance of the new Petrobras research centre, CENPES II, in Rio Janeiro, including free running and air-conditioned buildings. The architectural design was the subject of a national competition in 2004, encompassing over 100.000m2 and ten buildings. According to the design brief, four buildings should be naturally ventilated, whilst six had to be either air-conditioned, due to specific occupation requirements. In the case of naturally ventilated buildings, adaptive comfort was applied as performance criterion, and the environmental assessments were supported by advanced simulation tools. In most of the spaces within the free-running buildings the performance assessments showed environments with similar conditions to the exterior. Considering the working spaces pre-determined to be air-conditioned, the potential for natural ventilation in the working spaces reached 30% of occupation hours, justifying the case for the mixed-mode strategy. Este artigo apresenta um estudo do desempenho térmico dos edifícios do novo centro de pesquisas da Petrobras, CENPES II, no Rio de Janeiro, incluindo edifícios naturalmente ventilados e edifícios condicionados artificialmente. O projeto foi objeto de um concurso nacional em 2004, com um programa de 100.000m2 e dez edifícios. O edital propôs quatro edifícios naturalmente ventilados e outros seis artificialmente climatizados, pelas exigências do uso e especificidades da função. Nos edifícios com ventilação natural foi aplicado um modelo adaptativo de conforto térmico e as avaliações de desempenho foram realizadas com o suporte de ferramentas avançadas de simulação computacional. Na maioria dos ambientes com ventilação natural encontrou-se condições similares ao clima externo à sombra, comprovando a adequação da arquitetura ao clima. Nos ambientes de trabalho em que a climatização artificial foi colocada como premissa foi identificado, inicialmente, um potencial de 30% de ventilação natural durante as horas de ocupação, justificando a verificação das possibilidades do modo-misto de climatização. ANTAC - Associação Nacional de Tecnologia do Ambiente Construído 2010-01-26 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion application/pdf https://seer.ufrgs.br/ambienteconstruido/article/view/7794 Ambiente Construído; v. 10, n. 1 (2010); 7-29 Ambiente Construído; v. 10, n. 1 (2010); 7-29 Ambiente Construído; v. 10, n. 1 (2010); 7-29 1678-8621 1415-8876 por https://seer.ufrgs.br/ambienteconstruido/article/view/7794/7432 https://seer.ufrgs.br/ambienteconstruido/article/downloadSuppFile/7794/633 https://seer.ufrgs.br/ambienteconstruido/article/downloadSuppFile/7794/634 https://seer.ufrgs.br/ambienteconstruido/article/downloadSuppFile/7794/635 Direitos autorais 2016 Ambiente Construído https://creativecommons.org/licenses/by/4.0 |
| institution |
Universidade Federal do Rio Grande do Sul |
| collection |
OJS |
| language |
por |
| format |
Online |
| author |
Marcondes, Mônica Pereira Mueller, Cecília Mattos Brandão, Rafael Silva Prata, Alessandra Rodrigues Brunelli, Gustavo De Benedetto, Gisele Goncalves, Joana Soares Duarte, Denise Helena Silva Frota, Anésia Barros |
| spellingShingle |
Marcondes, Mônica Pereira Mueller, Cecília Mattos Brandão, Rafael Silva Prata, Alessandra Rodrigues Brunelli, Gustavo De Benedetto, Gisele Goncalves, Joana Soares Duarte, Denise Helena Silva Frota, Anésia Barros Thermal comfort and performance in the buildings of the new research centre of Petrobras in Rio de Janeiro |
| author_facet |
Marcondes, Mônica Pereira Mueller, Cecília Mattos Brandão, Rafael Silva Prata, Alessandra Rodrigues Brunelli, Gustavo De Benedetto, Gisele Goncalves, Joana Soares Duarte, Denise Helena Silva Frota, Anésia Barros |
| author_sort |
Marcondes, Mônica Pereira |
| title |
Thermal comfort and performance in the buildings of the new research centre of Petrobras in Rio de Janeiro |
| title_short |
Thermal comfort and performance in the buildings of the new research centre of Petrobras in Rio de Janeiro |
| title_full |
Thermal comfort and performance in the buildings of the new research centre of Petrobras in Rio de Janeiro |
| title_fullStr |
Thermal comfort and performance in the buildings of the new research centre of Petrobras in Rio de Janeiro |
| title_full_unstemmed |
Thermal comfort and performance in the buildings of the new research centre of Petrobras in Rio de Janeiro |
| title_sort |
thermal comfort and performance in the buildings of the new research centre of petrobras in rio de janeiro |
| description |
This paper presents the a study of the thermal performance of the new Petrobras research centre, CENPES II, in Rio Janeiro, including free running and air-conditioned buildings. The architectural design was the subject of a national competition in 2004, encompassing over 100.000m2 and ten buildings. According to the design brief, four buildings should be naturally ventilated, whilst six had to be either air-conditioned, due to specific occupation requirements. In the case of naturally ventilated buildings, adaptive comfort was applied as performance criterion, and the environmental assessments were supported by advanced simulation tools. In most of the spaces within the free-running buildings the performance assessments showed environments with similar conditions to the exterior. Considering the working spaces pre-determined to be air-conditioned, the potential for natural ventilation in the working spaces reached 30% of occupation hours, justifying the case for the mixed-mode strategy. |
| publisher |
ANTAC - Associação Nacional de Tecnologia do Ambiente Construído |
| publishDate |
2010 |
| url |
https://seer.ufrgs.br/ambienteconstruido/article/view/7794 |
| work_keys_str_mv |
AT marcondesmonicapereira thermalcomfortandperformanceinthebuildingsofthenewresearchcentreofpetrobrasinriodejaneiro AT muellerceciliamattos thermalcomfortandperformanceinthebuildingsofthenewresearchcentreofpetrobrasinriodejaneiro AT brandaorafaelsilva thermalcomfortandperformanceinthebuildingsofthenewresearchcentreofpetrobrasinriodejaneiro AT prataalessandrarodrigues thermalcomfortandperformanceinthebuildingsofthenewresearchcentreofpetrobrasinriodejaneiro AT brunelligustavo thermalcomfortandperformanceinthebuildingsofthenewresearchcentreofpetrobrasinriodejaneiro AT debenedettogisele thermalcomfortandperformanceinthebuildingsofthenewresearchcentreofpetrobrasinriodejaneiro AT goncalvesjoanasoares thermalcomfortandperformanceinthebuildingsofthenewresearchcentreofpetrobrasinriodejaneiro AT duartedenisehelenasilva thermalcomfortandperformanceinthebuildingsofthenewresearchcentreofpetrobrasinriodejaneiro AT frotaanesiabarros thermalcomfortandperformanceinthebuildingsofthenewresearchcentreofpetrobrasinriodejaneiro AT marcondesmonicapereira confortoedesempenhotermiconasedificacoesdonovocentrodepesquisasdapetrobrasnoriodejaneiro AT muellerceciliamattos confortoedesempenhotermiconasedificacoesdonovocentrodepesquisasdapetrobrasnoriodejaneiro AT brandaorafaelsilva confortoedesempenhotermiconasedificacoesdonovocentrodepesquisasdapetrobrasnoriodejaneiro AT prataalessandrarodrigues confortoedesempenhotermiconasedificacoesdonovocentrodepesquisasdapetrobrasnoriodejaneiro AT brunelligustavo confortoedesempenhotermiconasedificacoesdonovocentrodepesquisasdapetrobrasnoriodejaneiro AT debenedettogisele confortoedesempenhotermiconasedificacoesdonovocentrodepesquisasdapetrobrasnoriodejaneiro AT goncalvesjoanasoares confortoedesempenhotermiconasedificacoesdonovocentrodepesquisasdapetrobrasnoriodejaneiro AT duartedenisehelenasilva confortoedesempenhotermiconasedificacoesdonovocentrodepesquisasdapetrobrasnoriodejaneiro AT frotaanesiabarros confortoedesempenhotermiconasedificacoesdonovocentrodepesquisasdapetrobrasnoriodejaneiro |
| _version_ |
1709370619786690560 |