Green roofs as a passive cooling device in the tropics.
The study aims to determine the thermal performance of an experimental green-roof prototype that can be installed on pitched roofs of fiber cement corrugated sheets, widely used in our environment. Research results showed the advantages of using green roofs as a passive cooling device in the specifi...
में बचाया:
मुख्य लेखकों: | , , |
---|---|
स्वरूप: | Online |
भाषा: | spa |
प्रकाशित: |
Universidad Católica de Colombia
2017
|
ऑनलाइन पहुंच: | https://revistadearquitectura.ucatolica.edu.co/article/view/1109 |
टैग : |
टैग जोड़ें
कोई टैग नहीं, इस रिकॉर्ड को टैग करने वाले पहले व्यक्ति बनें!
|
id |
oai:editorial.ucatolica.edu.co:article-1109 |
---|---|
record_format |
ojs |
institution |
Universidad Católica de Colombia |
collection |
OJS |
language |
spa |
format |
Online |
author |
Osuna-Motta, Iván Herrera-Cáceres, Carlos López-Bernal, Oswaldo |
spellingShingle |
Osuna-Motta, Iván Herrera-Cáceres, Carlos López-Bernal, Oswaldo Green roofs as a passive cooling device in the tropics. |
author_facet |
Osuna-Motta, Iván Herrera-Cáceres, Carlos López-Bernal, Oswaldo |
author_sort |
Osuna-Motta, Iván |
title |
Green roofs as a passive cooling device in the tropics. |
title_short |
Green roofs as a passive cooling device in the tropics. |
title_full |
Green roofs as a passive cooling device in the tropics. |
title_fullStr |
Green roofs as a passive cooling device in the tropics. |
title_full_unstemmed |
Green roofs as a passive cooling device in the tropics. |
title_sort |
green roofs as a passive cooling device in the tropics. |
description |
The study aims to determine the thermal performance of an experimental green-roof prototype that can be installed on pitched roofs of fiber cement corrugated sheets, widely used in our environment. Research results showed the advantages of using green roofs as a passive cooling device in the specific climate and weather conditions of a place such as Cali, Colombia, where roofs are the greatest source of heat gain. During the experimental phase, a control module and two test modules were built, where the green-roof prototypes were installed; surface temperature of the envelope and temperature and relative humidity of indoor and outdoor air were periodically recorded. Using a comparative method, it was possible to establish and quantify the positive effect of the prototype on the thermal performance of the envelope in local conditions, demonstrating its usefulness. |
publisher |
Universidad Católica de Colombia |
publishDate |
2017 |
url |
https://revistadearquitectura.ucatolica.edu.co/article/view/1109 |
work_keys_str_mv |
AT osunamottaivan greenroofsasapassivecoolingdeviceinthetropics AT herreracacerescarlos greenroofsasapassivecoolingdeviceinthetropics AT lopezbernaloswaldo greenroofsasapassivecoolingdeviceinthetropics AT osunamottaivan techoplantadocomodispositivodeclimatizacionpasivaeneltropico AT herreracacerescarlos techoplantadocomodispositivodeclimatizacionpasivaeneltropico AT lopezbernaloswaldo techoplantadocomodispositivodeclimatizacionpasivaeneltropico AT osunamottaivan telhadosverdescomodispositivodeclimatizacaopassivanotropico AT herreracacerescarlos telhadosverdescomodispositivodeclimatizacaopassivanotropico AT lopezbernaloswaldo telhadosverdescomodispositivodeclimatizacaopassivanotropico |
_version_ |
1709645521411375104 |
spelling |
oai:editorial.ucatolica.edu.co:article-11092020-07-27T17:29:54Z Green roofs as a passive cooling device in the tropics. Techo plantado como dispositivo de climatización pasiva en el trópico. Telhados verdes como dispositivo de climatização passiva no trópico. Osuna-Motta, Iván Herrera-Cáceres, Carlos López-Bernal, Oswaldo heat transfer passive cooling sustainability thermal comfort green roofs confort térmico enfriamiento pasivo sostenibilidad transferencia de calor techos verdes conforto térmico refrigeração passiva sustentabilidade telhados verdes transferência de calor The study aims to determine the thermal performance of an experimental green-roof prototype that can be installed on pitched roofs of fiber cement corrugated sheets, widely used in our environment. Research results showed the advantages of using green roofs as a passive cooling device in the specific climate and weather conditions of a place such as Cali, Colombia, where roofs are the greatest source of heat gain. During the experimental phase, a control module and two test modules were built, where the green-roof prototypes were installed; surface temperature of the envelope and temperature and relative humidity of indoor and outdoor air were periodically recorded. Using a comparative method, it was possible to establish and quantify the positive effect of the prototype on the thermal performance of the envelope in local conditions, demonstrating its usefulness. Se determina el comportamiento térmico de un prototipo experimental de techo plantado, que pueda ser instalado sobre sistemas de cubiertas inclinadas en láminas onduladas de fibrocemento, ampliamente utilizas en nuestro medio. La investigación demostró las ventajas del uso de los techos plantados como dispositivos de enfriamiento pasivo, en las condiciones climáticas y meteorológicas específicas de la ciudad de Cali, donde la cubierta representa la mayor fuente de ganancia térmica. Durante la fase experimental, se construyeron un módulo testigo y dos módulos de prueba sobre los cuales se instalaron los prototipos y se registraron periódicamente los valores de temperatura superficial de la envolvente, y de temperatura y humedad relativa del aire exterior e interior. Utilizando un método comparativo, se pudo establecer y cuantificar el efecto positivo del prototipo sobre el comportamiento térmico de la envolvente en las condiciones locales, demostrando su utilidad. Determina-se o comportamento térmico de um protótipo experimental de telhado verde que possa ser instalado sobre sistemas de coberturas inclinadas em telhas de fibrocimento, amplamente utilizadas em nosso meio. Esta pesquisa demonstrou as vantagens do uso dos telhados verdes como dispositivos de climatização passiva, nas condições climáticas e meteorológicas específicas da cidade de Cali (Colômbia), onde o telhado representa a maior fonte de ganho de calor. Durante a fase experimental, foram construídos um módulo de controle e dois módulos de prova sobre os quais foram instalados os protótipos e registrados periodicamente os valores de temperatura superficial da envolvente e temperatura e umidade relativa do ar exterior e interior. Utilizando um método comparativo, pôde-se estabelecer e quantificar o efeito positivo do protótipo sobre o comportamento térmico da envolvente nas condições locais, demonstrando sua utilidade. Universidad Católica de Colombia 2017-04-20 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion text/html application/pdf application/epub+zip application/xml application/zip https://revistadearquitectura.ucatolica.edu.co/article/view/1109 10.14718/RevArq.2017.19.1.1109 Revista de Arquitectura; Vol. 19 No. 1 (2017): January - June; 42-55 Revista de Arquitectura (Bogotá); Vol. 19 Núm. 1 (2017): Enero - junio; 42-55 Revista de Arquitectura; Vol. 19 No. 1 (2017): Enero - junio; 42-55 Revista de Arquitectura; v. 19 n. 1 (2017): Janeiro - junho; 42-55 2357-626X 1657-0308 spa https://revistadearquitectura.ucatolica.edu.co/article/view/1109/1369 https://revistadearquitectura.ucatolica.edu.co/article/view/1109/pdf%2006 https://revistadearquitectura.ucatolica.edu.co/article/view/1109/1885 https://revistadearquitectura.ucatolica.edu.co/article/view/1109/1942 https://revistadearquitectura.ucatolica.edu.co/article/view/1109/2768 Derechos de autor 2017 Iván Osuna-Motta info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc/4.0 |