PMV extension to evaluate thermal comfort of elderly women in naturally ventilated rooms
The aging of the population requires creating conditions for the elderly to live with quality. Buildings' thermal comfort is essential to achieve this goal. This research analyzes the Predicted Mean Vote (PMV) and its extension (PMVe) to assess elderly women's thermal comfort conditions, a...
Saved in:
Main Authors: | , , |
---|---|
Format: | Online |
Language: | por |
Published: |
Universidade Estadual de Campinas
2021
|
Online Access: | https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8658443 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:ojs.periodicos.sbu.unicamp.br:article-8658443 |
---|---|
record_format |
ojs |
institution |
Universidade Estadual de Campinas |
collection |
OJS |
language |
por |
format |
Online |
author |
Ruviaro, Raiana Spat Zambonato, Bruna Grigoletti, Giane de Campos |
spellingShingle |
Ruviaro, Raiana Spat Zambonato, Bruna Grigoletti, Giane de Campos PMV extension to evaluate thermal comfort of elderly women in naturally ventilated rooms |
author_facet |
Ruviaro, Raiana Spat Zambonato, Bruna Grigoletti, Giane de Campos |
author_sort |
Ruviaro, Raiana Spat |
title |
PMV extension to evaluate thermal comfort of elderly women in naturally ventilated rooms |
title_short |
PMV extension to evaluate thermal comfort of elderly women in naturally ventilated rooms |
title_full |
PMV extension to evaluate thermal comfort of elderly women in naturally ventilated rooms |
title_fullStr |
PMV extension to evaluate thermal comfort of elderly women in naturally ventilated rooms |
title_full_unstemmed |
PMV extension to evaluate thermal comfort of elderly women in naturally ventilated rooms |
title_sort |
pmv extension to evaluate thermal comfort of elderly women in naturally ventilated rooms |
description |
The aging of the population requires creating conditions for the elderly to live with quality. Buildings' thermal comfort is essential to achieve this goal. This research analyzes the Predicted Mean Vote (PMV) and its extension (PMVe) to assess elderly women's thermal comfort conditions, aged 60 years or above. The study was conducted in two naturally ventilated senior homes in Santa Maria, RS, region with a temperate climate and hot summer. The study measured air temperature, air relative humidity, globe temperature, and air velocity. The study also performed a data survey on the perception and thermal preferences, clothing, and metabolic activity of the elderly. Then, the comfort sensation index was calculated. Users' thermal sensation was compared with PMV and PMVe, considering expectation factors of 0.5, 0.7, and 0.9. Comparing the three PMVe values, we could estimate that the lower the expectation factor, the smaller the difference between the PMVe and the negative thermal sensation votes (cold). The PMVe with correction factor 0.5 presented a perfect correlation for the PMV variables and the thermal sensation to 11.54% of the measurements. In contrast, the PMVe of 0.7 and 0.9 showed no points over the correlation reference line. The study demonstrated that the PMV extension does not correct the PMV inaccuracies but reduces the thermal sensation's differences, reducing the cold sensation overestimation of PMV results for elderly women. |
publisher |
Universidade Estadual de Campinas |
publishDate |
2021 |
url |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8658443 |
work_keys_str_mv |
AT ruviaroraianaspat pmvextensiontoevaluatethermalcomfortofelderlywomeninnaturallyventilatedrooms AT zambonatobruna pmvextensiontoevaluatethermalcomfortofelderlywomeninnaturallyventilatedrooms AT grigolettigianedecampos pmvextensiontoevaluatethermalcomfortofelderlywomeninnaturallyventilatedrooms AT ruviaroraianaspat extensaodopmvparaavaliacaodoconfortotermicodeidosasemambientescomventilacaonatural AT zambonatobruna extensaodopmvparaavaliacaodoconfortotermicodeidosasemambientescomventilacaonatural AT grigolettigianedecampos extensaodopmvparaavaliacaodoconfortotermicodeidosasemambientescomventilacaonatural |
_version_ |
1709640975457976320 |
spelling |
oai:ojs.periodicos.sbu.unicamp.br:article-86584432021-01-19T13:12:37Z PMV extension to evaluate thermal comfort of elderly women in naturally ventilated rooms Extensão do PMV para avaliação do conforto térmico de idosas em ambientes com ventilação natural Ruviaro, Raiana Spat Zambonato, Bruna Grigoletti, Giane de Campos Thermal comfort Elderly women PMV Conforto térmico Idosas PMV The aging of the population requires creating conditions for the elderly to live with quality. Buildings' thermal comfort is essential to achieve this goal. This research analyzes the Predicted Mean Vote (PMV) and its extension (PMVe) to assess elderly women's thermal comfort conditions, aged 60 years or above. The study was conducted in two naturally ventilated senior homes in Santa Maria, RS, region with a temperate climate and hot summer. The study measured air temperature, air relative humidity, globe temperature, and air velocity. The study also performed a data survey on the perception and thermal preferences, clothing, and metabolic activity of the elderly. Then, the comfort sensation index was calculated. Users' thermal sensation was compared with PMV and PMVe, considering expectation factors of 0.5, 0.7, and 0.9. Comparing the three PMVe values, we could estimate that the lower the expectation factor, the smaller the difference between the PMVe and the negative thermal sensation votes (cold). The PMVe with correction factor 0.5 presented a perfect correlation for the PMV variables and the thermal sensation to 11.54% of the measurements. In contrast, the PMVe of 0.7 and 0.9 showed no points over the correlation reference line. The study demonstrated that the PMV extension does not correct the PMV inaccuracies but reduces the thermal sensation's differences, reducing the cold sensation overestimation of PMV results for elderly women. O envelhecimento populacional torna necessário criar condições para que idosos vivam com qualidade de vida. O conforto térmico das edificações é fundamental para atingir essa meta. Esta pesquisa analisou a aplicabilidade do Voto Médio Estimado (PMV) e a sua extensão (PMVe) para avaliação do conforto térmico de idosas, com idade igual ou superior a 60 anos. O estudo foi aplicado em dois residenciais geriátricos naturalmente ventilados localizados em Santa Maria, RS, região de clima temperado com verão quente. As variáveis ambientais temperatura do ar, umidade relativa do ar, temperatura de globo e velocidade do ar foram medidas e foram aplicados questionários para o levantamento da sensação e preferência térmicas das idosas e das variáveis vestimenta e atividade metabólica. Então, calculou-se o índice de sensação de conforto. A sensação térmica real dos usuários foi comparada com o PMV e o PMVe, com fatores de correção de 0,5, 0,7 e 0,9. Comparando os três valores de PMVe, estimou-se que, quanto menor o fator expectativa, menor é a diferença entre PMVe e sensação térmica para valores negativos (frio). O PMVe com fator de correção 0,5 apresentou perfeita correlação das variáveis PMV e sensação térmica relatada em 11,54% das medições, já o PMVe de 0,7 e de 0,9 não apresentaram nenhum ponto sobre a reta de referência. O estudo mostrou que a extensão do PMV não corrige as imprecisões do modelo, mas reduz as diferenças encontradas com os valores de sensação térmica relatada, diminuindo a superestimação da sensação de frio que o PMV resultava para as idosas. Universidade Estadual de Campinas 2021-01-19 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Text Texto texto application/pdf https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8658443 10.20396/parc.v12i00.8658443 PARC Pesquisa em Arquitetura e Construção; Vol. 12 (2021): Continous publication; e021002 PARC Pesquisa em Arquitetura e Construção; Vol. 12 (2021): Publicação contínua; e021002 PARC Pesquisa em Arquitetura e Construção; v. 12 (2021): Publicação contínua; e021002 1980-6809 por https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8658443/25833 Brazil; Contemporary artigo Brasil; Contemporâneo Copyright (c) 2021 PARC Pesquisa em Arquitetura e Construção https://creativecommons.org/licenses/by/4.0 |