Using air-conditioning waste water and stormwater as supply management in a commercial building, case study

O conceito do uso racional para a conservação de água consiste na gestão da demanda e da oferta de água, com ações voltadas para o fornecimento de fontes alternativas visando suprir o uso em áreas menos nobres por águas de qualidade inferior. Este trabalho tem por objetivo mostrar a aplicação de um...

Mô tả đầy đủ

Đã lưu trong:
Chi tiết về thư mục
Những tác giả chính: Bastos, Celso Silva, Calmon, João Luiz
Định dạng: Online
Ngôn ngữ:spa
Được phát hành: Universidad del Bío-Bío, Chile 2013
Truy cập trực tuyến:https://revistas.ubiobio.cl/index.php/RHS/article/view/436
Các nhãn: Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
id oai:ojs.revistas.ubiobio.cl:article-436
record_format ojs
spelling oai:ojs.revistas.ubiobio.cl:article-4362018-03-27T16:12:13Z Using air-conditioning waste water and stormwater as supply management in a commercial building, case study Uso de água residual do ar condicionado e de agua pluvial como gestão da oferta em uma edificação comercial: estudo de caso Bastos, Celso Silva Calmon, João Luiz aproveitamento de água de chuva construções verdes sustentabilidade Utilization of rainwater green buildings sustainability O conceito do uso racional para a conservação de água consiste na gestão da demanda e da oferta de água, com ações voltadas para o fornecimento de fontes alternativas visando suprir o uso em áreas menos nobres por águas de qualidade inferior. Este trabalho tem por objetivo mostrar a aplicação de um sistema que aproveita a água drenada dos evaporadores de ar-condicionado e das águas pluviais como fontes alternativas. Verificou-se que cada evaporador produz 4,8 litros/água/hora, considerando 10 horas de uso diário, o volume acumulado chegaria a 48 litros/dia por aparelho que multiplicado pelo total de 137 unidades chega-se ao volume diário de 4.298 litros o que representa 77,72% da demanda das descargas sanitárias que é de 5.530 litros/dia. Em relação ao aproveitamento de águas pluviais, a previsão de acumulação refere-se a 10% da área do terreno que multiplicado pelo índice de 0,05 e pela retenção de 1 hora, obtém o volume de 14,8 m3 . Pretende-se com essa prática, alcançar uma redução significativa do volume de água potável, hoje utilizada praticamente para a realização de todas as atividades, contribuindo assim para uma obra mais sustentável, minimizando os impactos ambientais causados pela construção. The concept of rational use as applied to water conservation consists in managing water supply and demand by trying to meet lesser quality water demands with alternative or reused water supply. This project attempts to demonstrate the application of a system that uses water drained from air conditioning system evaporators and rainwater as alternative sources. Given that each evaporator produces 4.80 liters of water per hour and considering the average use of an air conditioning system to be approximately 10 hours per day, the daily total of a single evaporator would be 48 liters. This would implicate a daily volume of 4,298 liters for the whole 137 units spread throughout the building, which in time would represent 77.72% of the daily demand of wastewater (5,53 liter/day). For the rainwater collection system, the total accumulated volume corresponds to 10% of the site area multiplied by a factor of 0.05, for a retention time of 1 hour, which will produce a total volume 14.8m³ of water. This system´s primary objective is to significantly reduce the consumption of potable water, which nowadays is used for every single activity, thus contributing to a more sustainable building and minimizing the environmental impact caused by the construction. Universidad del Bío-Bío, Chile 2013-12-31 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artículo revisado por pares application/pdf https://revistas.ubiobio.cl/index.php/RHS/article/view/436 Hábitat Sustentable; V.3, N.2 (2013): Diciembre; 66-74 Sustainable Habitat; V.3, N.2 (2013): Diciembre; 66-74 0719-0700 spa https://revistas.ubiobio.cl/index.php/RHS/article/view/436/398 Derechos de autor 2015 Revista Hábitat Sustentable
institution Universidad del Bío-Bío
collection OJS
language spa
format Online
author Bastos, Celso Silva
Calmon, João Luiz
spellingShingle Bastos, Celso Silva
Calmon, João Luiz
Using air-conditioning waste water and stormwater as supply management in a commercial building, case study
author_facet Bastos, Celso Silva
Calmon, João Luiz
author_sort Bastos, Celso Silva
title Using air-conditioning waste water and stormwater as supply management in a commercial building, case study
title_short Using air-conditioning waste water and stormwater as supply management in a commercial building, case study
title_full Using air-conditioning waste water and stormwater as supply management in a commercial building, case study
title_fullStr Using air-conditioning waste water and stormwater as supply management in a commercial building, case study
title_full_unstemmed Using air-conditioning waste water and stormwater as supply management in a commercial building, case study
title_sort using air-conditioning waste water and stormwater as supply management in a commercial building, case study
description O conceito do uso racional para a conservação de água consiste na gestão da demanda e da oferta de água, com ações voltadas para o fornecimento de fontes alternativas visando suprir o uso em áreas menos nobres por águas de qualidade inferior. Este trabalho tem por objetivo mostrar a aplicação de um sistema que aproveita a água drenada dos evaporadores de ar-condicionado e das águas pluviais como fontes alternativas. Verificou-se que cada evaporador produz 4,8 litros/água/hora, considerando 10 horas de uso diário, o volume acumulado chegaria a 48 litros/dia por aparelho que multiplicado pelo total de 137 unidades chega-se ao volume diário de 4.298 litros o que representa 77,72% da demanda das descargas sanitárias que é de 5.530 litros/dia. Em relação ao aproveitamento de águas pluviais, a previsão de acumulação refere-se a 10% da área do terreno que multiplicado pelo índice de 0,05 e pela retenção de 1 hora, obtém o volume de 14,8 m3 . Pretende-se com essa prática, alcançar uma redução significativa do volume de água potável, hoje utilizada praticamente para a realização de todas as atividades, contribuindo assim para uma obra mais sustentável, minimizando os impactos ambientais causados pela construção.
publisher Universidad del Bío-Bío, Chile
publishDate 2013
url https://revistas.ubiobio.cl/index.php/RHS/article/view/436
work_keys_str_mv AT bastoscelsosilva usingairconditioningwastewaterandstormwaterassupplymanagementinacommercialbuildingcasestudy
AT calmonjoaoluiz usingairconditioningwastewaterandstormwaterassupplymanagementinacommercialbuildingcasestudy
AT bastoscelsosilva usodeaguaresidualdoarcondicionadoedeaguapluvialcomogestaodaofertaemumaedificacaocomercialestudodecaso
AT calmonjoaoluiz usodeaguaresidualdoarcondicionadoedeaguapluvialcomogestaodaofertaemumaedificacaocomercialestudodecaso
_version_ 1709638126249443328