Evaluation of the termolosa system between experimental measurement and calculation with Normative NMX-C-460-ONNCCE-2009

The evaluation of the prefabricated roof component called "Termolosa" is presented, comparing the results of the thermal resistance (R), using the thermal conductivity data obtained based on the ASTM C177-97 standard (stable state test method by means of Guarded-Hot-Plate Apparatus), and t...

全面介绍

Saved in:
书目详细资料
主要作者: Ruiz Torres, Raúl Pavel
格式: Online
语言:spa
出版: Centro Universitario de Arte, Arquitectura y Diseño 2019
在线阅读:https://www.revistavivienda.cuaad.udg.mx/index.php/rv/article/view/126
标签: 添加标签
没有标签, 成为第一个标记此记录!
实物特征
总结:The evaluation of the prefabricated roof component called "Termolosa" is presented, comparing the results of the thermal resistance (R), using the thermal conductivity data obtained based on the ASTM C177-97 standard (stable state test method by means of Guarded-Hot-Plate Apparatus), and the one calculated by the Mexican standard NMX-C-460-ONNCCE-2009, Construction industry, thermal insulation-value "R" for housing envelopes by thermal zone for the Mexican Republic, specifications and verification, The results indicate that the variations are due to the values ​​indicated in the standard, obviating that there are differences in properties between the materials used for the construction, so that the Thermal Resistance is different and for Therefore, when applied with the calculation in standards such as NOM-020-ENER-2011, Energy efficiency in buildings, the heat gain values ​​in the envelope are different.