Analysis of the use of air-admittance valves in Brazilian sanitary sewer systems
This article presents an analysis of the ventilation conditions inside sanitary sewer systems of residential buildings when the secondary ventilation, usually accomplished by means of branches and columns, is replaced by air-admittance valves. Three tests were performed in prototypes of sanitary sew...
Đã lưu trong:
Những tác giả chính: | , |
---|---|
Định dạng: | Online |
Ngôn ngữ: | por |
Được phát hành: |
ANTAC - Associação Nacional de Tecnologia do Ambiente Construído
2008
|
Truy cập trực tuyến: | https://seer.ufrgs.br/ambienteconstruido/article/view/3431 |
Các nhãn: |
Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
|
Tóm tắt: | This article presents an analysis of the ventilation conditions inside sanitary sewer systems of residential buildings when the secondary ventilation, usually accomplished by means of branches and columns, is replaced by air-admittance valves. Three tests were performed in prototypes of sanitary sewer systems associated to Brazilian building typologies, in which the pressure in different points of the system was measured, and the performance of seal traps was assessed. The prototypes were tested with several sanitary appliance flow arrangements, as well as with different types of ventilation systems, always starting with the sanitary sewer system which had only primary ventilation.The aim of this work is to provide designers of building sanitary sewer systems with guidelines for safely conceiving and dimensioning the ventilation subsystem, as well as replacing secondary ventilation pipes by air-admittance valves. . |
---|