Analysis of the use of air-admittance valves in Brazilian sanitary sewer systems

This article presents an analysis of the ventilation conditions inside sanitary sewer systems of residential buildings when the secondary ventilation, usually accomplished by means of branches and columns, is replaced by air-admittance valves. Three tests were performed in prototypes of sanitary sew...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Asıl Yazarlar: Fernandes, Vera Maria Cartana, Gonçalves, Orestes Marraccini
Materyal Türü: Online
Dil:por
Baskı/Yayın Bilgisi: ANTAC - Associação Nacional de Tecnologia do Ambiente Construído 2008
Online Erişim:https://seer.ufrgs.br/ambienteconstruido/article/view/3431
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!
id ojs-article-3431
record_format ojs
spelling ojs-article-34312008-11-21T23:44:52Z Analysis of the use of air-admittance valves in Brazilian sanitary sewer systems Análise do uso de válvulas de admissão de ar nos sistemas de esgotos sanitários brasileiros Fernandes, Vera Maria Cartana Gonçalves, Orestes Marraccini Esgoto sanitário; Sistema de ventilação; Ventilação secundária; Válvula de admissão de ar This article presents an analysis of the ventilation conditions inside sanitary sewer systems of residential buildings when the secondary ventilation, usually accomplished by means of branches and columns, is replaced by air-admittance valves. Three tests were performed in prototypes of sanitary sewer systems associated to Brazilian building typologies, in which the pressure in different points of the system was measured, and the performance of seal traps was assessed. The prototypes were tested with several sanitary appliance flow arrangements, as well as with different types of ventilation systems, always starting with the sanitary sewer system which had only primary ventilation.The aim of this work is to provide designers of building sanitary sewer systems with guidelines for safely conceiving and dimensioning the ventilation subsystem, as well as replacing secondary ventilation pipes by air-admittance valves. . Este artigo apresenta uma análise das condições de ventilação dentro do Sistema de Esgoto Sanitário de edifícios residenciais, quando a ventilação secundária, realizada por meio de ramais e colunas de ventilação, é substituída por válvulas de admissão de ar. Foram realizados ensaios em protótipos de sistemas prediais de esgotos sanitários de tipologias brasileiras, sendo avaliadas as pressões em diversos pontos dos sistemas, como também o comportamento dos fechos hídricos dos desconectores presentes nas instalações. Os protótipos foram ensaiados com diversos arranjos de descarga dos aparelhos sanitários, como também com diferentes tipos de sistema de ventilação, sempre a partir do sistema de esgoto sanitário dotado apenas de ventilação primária. Assim, pretende-se com este trabalho fornecer subsídios para que os projetistas de sistemas prediais de esgotos sanitários possam conceber e dimensionar com maior segurança o subsistema de ventilação, como também utilizar válvulas de admissão de ar em substituição à ventilação secundária realizada com tubulações. ANTAC - Associação Nacional de Tecnologia do Ambiente Construído 2008-04-14 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion application/pdf https://seer.ufrgs.br/ambienteconstruido/article/view/3431 Ambiente Construído; v. 2, n. 4 (2002): Edição Especial Sistemas Prediais; 19-26 Ambiente Construído; v. 2, n. 4 (2002): Edição Especial Sistemas Prediais; 19-26 Ambiente Construído; v. 2, n. 4 (2002): Edição Especial Sistemas Prediais; 19-26 1678-8621 1415-8876 por https://seer.ufrgs.br/ambienteconstruido/article/view/3431/1848 Direitos autorais 2016 Ambiente Construído https://creativecommons.org/licenses/by/4.0
institution Universidade Federal do Rio Grande do Sul
collection OJS
language por
format Online
author Fernandes, Vera Maria Cartana
Gonçalves, Orestes Marraccini
spellingShingle Fernandes, Vera Maria Cartana
Gonçalves, Orestes Marraccini
Analysis of the use of air-admittance valves in Brazilian sanitary sewer systems
author_facet Fernandes, Vera Maria Cartana
Gonçalves, Orestes Marraccini
author_sort Fernandes, Vera Maria Cartana
title Analysis of the use of air-admittance valves in Brazilian sanitary sewer systems
title_short Analysis of the use of air-admittance valves in Brazilian sanitary sewer systems
title_full Analysis of the use of air-admittance valves in Brazilian sanitary sewer systems
title_fullStr Analysis of the use of air-admittance valves in Brazilian sanitary sewer systems
title_full_unstemmed Analysis of the use of air-admittance valves in Brazilian sanitary sewer systems
title_sort analysis of the use of air-admittance valves in brazilian sanitary sewer systems
description This article presents an analysis of the ventilation conditions inside sanitary sewer systems of residential buildings when the secondary ventilation, usually accomplished by means of branches and columns, is replaced by air-admittance valves. Three tests were performed in prototypes of sanitary sewer systems associated to Brazilian building typologies, in which the pressure in different points of the system was measured, and the performance of seal traps was assessed. The prototypes were tested with several sanitary appliance flow arrangements, as well as with different types of ventilation systems, always starting with the sanitary sewer system which had only primary ventilation.The aim of this work is to provide designers of building sanitary sewer systems with guidelines for safely conceiving and dimensioning the ventilation subsystem, as well as replacing secondary ventilation pipes by air-admittance valves. .
publisher ANTAC - Associação Nacional de Tecnologia do Ambiente Construído
publishDate 2008
url https://seer.ufrgs.br/ambienteconstruido/article/view/3431
work_keys_str_mv AT fernandesveramariacartana analysisoftheuseofairadmittancevalvesinbraziliansanitarysewersystems
AT goncalvesorestesmarraccini analysisoftheuseofairadmittancevalvesinbraziliansanitarysewersystems
AT fernandesveramariacartana analisedousodevalvulasdeadmissaodearnossistemasdeesgotossanitariosbrasileiros
AT goncalvesorestesmarraccini analisedousodevalvulasdeadmissaodearnossistemasdeesgotossanitariosbrasileiros
_version_ 1709370613476360192