Limit conditions for the use of single stack in residential building sanitary sewer systems
This article presents some limit conditions for the use of single stack in residential building sanitary sewer systems, through the evaluation of the ventilation conditions inside those systems. Tests were performed in prototypes of building sanitary sewer systems, considering Brazilian building typ...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Online |
| Language: | por |
| Published: |
ANTAC - Associação Nacional de Tecnologia do Ambiente Construído
2008
|
| Online Access: | https://seer.ufrgs.br/ambienteconstruido/article/view/3675 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| id |
ojs-article-3675 |
|---|---|
| record_format |
ojs |
| spelling |
ojs-article-36752008-11-21T23:47:43Z Limit conditions for the use of single stack in residential building sanitary sewer systems Condições-limite para utilização do sistema de tubo de queda único nos sistemas prediais de coleta de esgoto sanitário residencial Fernandes, Vera Maria Cartana Gonçalves, Orestes Marraccini sistemas prediais; sistema predial de esgoto sanitário; sistema de ventilação; ventilação primária This article presents some limit conditions for the use of single stack in residential building sanitary sewer systems, through the evaluation of the ventilation conditions inside those systems. Tests were performed in prototypes of building sanitary sewer systems, considering Brazilian building typologies, in which the pressures in different points of the systems were evaluated, as well as the behaviour of seal traps. The prototypes were tested with several sanitary appliance flow arrangements and different diameters, all of them having only primary ventilation. The aim of this study is to provide building drainage system designers with safer conditions for using that type of ventilation system, which was introduced in the latest revision of NBR 8160 – Building Sanitary Sewer Systems – Design and execution – Procedures. Este artigo apresentada algumas condições-limite de utilização do sistema de tubo de queda único em sistemas de esgoto sanitário residencial, através da avaliação das condições de ventilação dentro desses sistemas. Foram realizados ensaios em protótipos de sistemas prediais de esgoto sanitário residencial, usando tipologias de edificações brasileiras, em que foram analisadas as pressões em diversos pontos dos sistemas, como também o comportamento dos fechos hídricos dos desconectores. Os protótipos foram ensaiados com diversos arranjos de descarga e diâmetros de tubulações, todos dotados apenas da ventilação primária. O objetivo desta pesquisa é proporcionar aos projetistas de sistemas hidráulicos prediais condições mais seguras de utilização desse tipo de subsistema de ventilação, o qual foi introduzido na última revisão da NBR 8160 – Sistemas prediais de esgoto sanitário – Projeto e execução – Procedimento. ANTAC - Associação Nacional de Tecnologia do Ambiente Construído 2008-04-24 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion application/pdf https://seer.ufrgs.br/ambienteconstruido/article/view/3675 Ambiente Construído; v. 6, n. 1 (2006): Edição Especial Sistemas Prediais; 7-18 Ambiente Construído; v. 6, n. 1 (2006): Edição Especial Sistemas Prediais; 7-18 Ambiente Construído; v. 6, n. 1 (2006): Edição Especial Sistemas Prediais; 7-18 1678-8621 1415-8876 por https://seer.ufrgs.br/ambienteconstruido/article/view/3675/2041 Direitos autorais 2016 Ambiente Construído https://creativecommons.org/licenses/by/4.0 |
| institution |
Universidade Federal do Rio Grande do Sul |
| collection |
OJS |
| language |
por |
| format |
Online |
| author |
Fernandes, Vera Maria Cartana Gonçalves, Orestes Marraccini |
| spellingShingle |
Fernandes, Vera Maria Cartana Gonçalves, Orestes Marraccini Limit conditions for the use of single stack in residential building sanitary sewer systems |
| author_facet |
Fernandes, Vera Maria Cartana Gonçalves, Orestes Marraccini |
| author_sort |
Fernandes, Vera Maria Cartana |
| title |
Limit conditions for the use of single stack in residential building sanitary sewer systems |
| title_short |
Limit conditions for the use of single stack in residential building sanitary sewer systems |
| title_full |
Limit conditions for the use of single stack in residential building sanitary sewer systems |
| title_fullStr |
Limit conditions for the use of single stack in residential building sanitary sewer systems |
| title_full_unstemmed |
Limit conditions for the use of single stack in residential building sanitary sewer systems |
| title_sort |
limit conditions for the use of single stack in residential building sanitary sewer systems |
| description |
This article presents some limit conditions for the use of single stack in residential building sanitary sewer systems, through the evaluation of the ventilation conditions inside those systems. Tests were performed in prototypes of building sanitary sewer systems, considering Brazilian building typologies, in which the pressures in different points of the systems were evaluated, as well as the behaviour of seal traps. The prototypes were tested with several sanitary appliance flow arrangements and different diameters, all of them having only primary ventilation. The aim of this study is to provide building drainage system designers with safer conditions for using that type of ventilation system, which was introduced in the latest revision of NBR 8160 – Building Sanitary Sewer Systems – Design and execution – Procedures. |
| publisher |
ANTAC - Associação Nacional de Tecnologia do Ambiente Construído |
| publishDate |
2008 |
| url |
https://seer.ufrgs.br/ambienteconstruido/article/view/3675 |
| work_keys_str_mv |
AT fernandesveramariacartana limitconditionsfortheuseofsinglestackinresidentialbuildingsanitarysewersystems AT goncalvesorestesmarraccini limitconditionsfortheuseofsinglestackinresidentialbuildingsanitarysewersystems AT fernandesveramariacartana condicoeslimiteparautilizacaodosistemadetubodequedauniconossistemasprediaisdecoletadeesgotosanitarioresidencial AT goncalvesorestesmarraccini condicoeslimiteparautilizacaodosistemadetubodequedauniconossistemasprediaisdecoletadeesgotosanitarioresidencial |
| _version_ |
1709370652911206400 |