CFD simulation and measurement of the thermal behavior inside a room of the institutional library: a comparative study

This article presents the results of the comparison between the CFD simulation and temperature measurements, both in the time domain, at a certain point of interest within a specific closed space (cubicle) of the institutional library of the Salesian Polytechnic University (UPS), at its headquarters...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Asıl Yazarlar: Vázquez Silva, Efrén, Cajas-Muñoz, Franco David, Asitimbay-Deleg, Marcelo Xavier, Torres-Jara, Paúl Bolívar, Abad-Farfán, Gabriela
Materyal Türü: Online
Dil:eng
Baskı/Yayın Bilgisi: ANTAC - Associação Nacional de Tecnologia do Ambiente Construído 2019
Online Erişim:https://seer.ufrgs.br/ambienteconstruido/article/view/85457
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!
id ojs-article-85457
record_format ojs
spelling ojs-article-854572019-06-17T21:12:22Z CFD simulation and measurement of the thermal behavior inside a room of the institutional library: a comparative study Vázquez Silva, Efrén Cajas-Muñoz, Franco David Asitimbay-Deleg, Marcelo Xavier Torres-Jara, Paúl Bolívar Abad-Farfán, Gabriela solar radiation, heat transfer, CFD This article presents the results of the comparison between the CFD simulation and temperature measurements, both in the time domain, at a certain point of interest within a specific closed space (cubicle) of the institutional library of the Salesian Polytechnic University (UPS), at its headquarters in the city of Cuenca, Republic of Ecuador. In this specific case, solar radiation is considered as the main heat transfer mechanism, which is why it was considered in the applied simulation method. An acceptable relative error was obtained between the simulated and measured temperature values. During the summer period, the thermal conditions inside the cubicle are not suitable for the comfort of the users. The study developed can constitute a basic tool for possible future research related to the implementation of climate conditioning for the cubicle, the library in general and any other site with similar constructive and operational characteristics.During the summer period, the thermal conditions inside the cubicle are not suitable for the comfort of the users. The study developed can constitute a basic tool for possible future research related to the implementation of climate conditioning for the cubicle, the library in general and any other site with similar constructive and operational characteristics. ANTAC - Associação Nacional de Tecnologia do Ambiente Construído 2019-06-17 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion https://seer.ufrgs.br/ambienteconstruido/article/view/85457 Ambiente Construído; v. 19, n. 3 (2019); 183-195 Ambiente Construído; v. 19, n. 3 (2019); 183-195 Ambiente Construído; v. 19, n. 3 (2019); 183-195 1678-8621 1415-8876 eng https://seer.ufrgs.br/ambienteconstruido/article/view/85457/53052 Direitos autorais 2019 Ambiente Construído https://creativecommons.org/licenses/by/4.0
institution Universidade Federal do Rio Grande do Sul
collection OJS
language eng
format Online
author Vázquez Silva, Efrén
Cajas-Muñoz, Franco David
Asitimbay-Deleg, Marcelo Xavier
Torres-Jara, Paúl Bolívar
Abad-Farfán, Gabriela
spellingShingle Vázquez Silva, Efrén
Cajas-Muñoz, Franco David
Asitimbay-Deleg, Marcelo Xavier
Torres-Jara, Paúl Bolívar
Abad-Farfán, Gabriela
CFD simulation and measurement of the thermal behavior inside a room of the institutional library: a comparative study
author_facet Vázquez Silva, Efrén
Cajas-Muñoz, Franco David
Asitimbay-Deleg, Marcelo Xavier
Torres-Jara, Paúl Bolívar
Abad-Farfán, Gabriela
author_sort Vázquez Silva, Efrén
title CFD simulation and measurement of the thermal behavior inside a room of the institutional library: a comparative study
title_short CFD simulation and measurement of the thermal behavior inside a room of the institutional library: a comparative study
title_full CFD simulation and measurement of the thermal behavior inside a room of the institutional library: a comparative study
title_fullStr CFD simulation and measurement of the thermal behavior inside a room of the institutional library: a comparative study
title_full_unstemmed CFD simulation and measurement of the thermal behavior inside a room of the institutional library: a comparative study
title_sort cfd simulation and measurement of the thermal behavior inside a room of the institutional library: a comparative study
description This article presents the results of the comparison between the CFD simulation and temperature measurements, both in the time domain, at a certain point of interest within a specific closed space (cubicle) of the institutional library of the Salesian Polytechnic University (UPS), at its headquarters in the city of Cuenca, Republic of Ecuador. In this specific case, solar radiation is considered as the main heat transfer mechanism, which is why it was considered in the applied simulation method. An acceptable relative error was obtained between the simulated and measured temperature values. During the summer period, the thermal conditions inside the cubicle are not suitable for the comfort of the users. The study developed can constitute a basic tool for possible future research related to the implementation of climate conditioning for the cubicle, the library in general and any other site with similar constructive and operational characteristics.During the summer period, the thermal conditions inside the cubicle are not suitable for the comfort of the users. The study developed can constitute a basic tool for possible future research related to the implementation of climate conditioning for the cubicle, the library in general and any other site with similar constructive and operational characteristics.
publisher ANTAC - Associação Nacional de Tecnologia do Ambiente Construído
publishDate 2019
url https://seer.ufrgs.br/ambienteconstruido/article/view/85457
work_keys_str_mv AT vazquezsilvaefren cfdsimulationandmeasurementofthethermalbehaviorinsidearoomoftheinstitutionallibraryacomparativestudy
AT cajasmunozfrancodavid cfdsimulationandmeasurementofthethermalbehaviorinsidearoomoftheinstitutionallibraryacomparativestudy
AT asitimbaydelegmarceloxavier cfdsimulationandmeasurementofthethermalbehaviorinsidearoomoftheinstitutionallibraryacomparativestudy
AT torresjarapaulbolivar cfdsimulationandmeasurementofthethermalbehaviorinsidearoomoftheinstitutionallibraryacomparativestudy
AT abadfarfangabriela cfdsimulationandmeasurementofthethermalbehaviorinsidearoomoftheinstitutionallibraryacomparativestudy
_version_ 1709370659039084544