Evaluation of the termolosa system between experimental measurement and calculation with Normative NMX-C-460-ONNCCE-2009

The evaluation of the prefabricated roof component called "Termolosa" is presented, comparing the results of the thermal resistance (R), using the thermal conductivity data obtained based on the ASTM C177-97 standard (stable state test method by means of Guarded-Hot-Plate Apparatus), and t...

Full description

Saved in:
Bibliographic Details
Main Author: Ruiz Torres, Raúl Pavel
Format: Online
Language:spa
Published: Centro Universitario de Arte, Arquitectura y Diseño 2019
Online Access:https://www.revistavivienda.cuaad.udg.mx/index.php/rv/article/view/126